![]() This can be done at this time (the init.exe here is what I found casually A file, and ipmsg not necessarily, just for demonstration): The main program can only run well after init.exe is run once. Imagine that there is a main program called ipmsg.exe and an initialization program called init.exe. At this time, you can use the Run section to specify the program to be executed after the program is installed and before the installation program displays the final dialog box. net Framework to be installed on the computer, otherwise the main program cannot run, and the main program can only be run after the NET Framework is installed in advance. An obvious example is that many programs are currently developed through NET technology, which requires the. If these programs are not executed, the main program cannot complete the work well, or even complete the work. So is there a way to compile CodeSection.txt for use or to integrate it in installer.Sometimes our program can complete the installation well, but the configuration of the program may need other programs to assist in completion. There are " and some pascal code" throughout the file and it results in error "invalid section tag". In installer.iss I created section tag and pasted the whole contents of whole CodeSection.txt file there,thinking that It might work.īut after clicking Run in Inno Setup Studio.Įrror came : Invalid section tag at line : RT. I tried to add the Contents of CodeSection.txt in installer.iss using: Is CodeSection.txt worth modifying to get the expected compressed file (here, data01.bin) uncompressed ? I searched the names of compressed files in CodeSection.txt using notepad++.Īnd I got the names of all of them in the CodeSection.txt file but file is written in Pascal and I do not know if I can use it to just decompress one file at a time. It extracted these files from inno setup :įrom internet I got to know that folder contain all the files used in compression but installer.iss doesn't contain any information about compressed files (data01.bin etc).įrom internet I got to know that CodeSection.txt is the decompiled file of CompileCode.bin. So I extracted the setup.exe using "inno extract" utility. So I thought I might be able to decompress files if I got the code of Installer. I checked the integrity of files and all were complete and uncorrupted. Problem is, it takes to much time to decompress (8 - 11 hrs) as ETA given by installer.Īnd after 69% throws error such as "unarc error : corrupted archive". The whole file is 8 GB and after install it should take 21 GB of space. I have an inno setup which decompresses some files from data01.bin, data02.bin etc. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |